| IP rating |
IP30
|
| Temperature measuring range |
-200...1090°C
|
| Kind of display used |
LCD (6000/20000),
with a backlit
|
| Overall dimensions (W x D x H) |
95x48x200mm
|
| DC current measuring range |
0,1µ...600µ/6000µ/60m/400m/6/10A (20A during 30s)
|
| AC current measuring range |
0,1µ...600µ/6000µ/60m/400m/6/10A (20A during 30s)
|
| Power supply |
1 battery 9V 6F22
|
| Frequency measuring range |
0,01...199,99/1999,9/19,999k/199,99k/>200kHz
|
| Conform to the norm |
EN61010 1000V CAT III,
EN61010 600V CAT IV
|
| Optional equipment |
400A AC/DC FLK-I410 current clamp probe,
FLK-C25 soft cover,
FLK-TL238 set,
FLK-TOOLPAK strap with magnet for suspending the meter
|
| Measuring instrument features |
auto and manual ranging,
automatic power-off,
built-in thermometer,
filter ensuring voltage and frequency measuring accuracy,
HOLD function,
impact resistant holster,
indicates incorrect connection of test leads,
MIN/MAX/MEDIUM function,
PEAK HOLD function,
test leads resistance compensation
|
| Standard equipment |
battery,
crocodile clips FLK-AC72,
FLK-80BK-A drop-like K-type temperature probe,
FLK-I410 - current clamp,
FLK-L215 set,
FLK-TL75 test leads
|
| DC voltage measuring range |
0,1m...600m/6/60/600/1000V
|
| Type of meter |
digital multimeter
|
| AC voltage measuring range |
0,1m...600m/6/60/600/1000V
|
| Resistance measuring range |
0,1...600/6k/60k/600k/6M/50MΩ
|
| Weight with battery |
600g
|
| Capacitance measuring range |
0,01n...10n/100n/1µ/10µ/100µ/9999µF
|
| True effective value measurement |
True RMS AC
|